Working Principle of Fresh Water Generator on Board Ship

Working Principle of Fresh Water Generator on Board Ship

Fresh water generator(FWG) is one of the essential machineries on board ship, After-all a large amount of fresh water is utilized on ship every day. On board ship Fresh water is used for the most part by huge boilers having steam turbines as main propulsion or cargo pumps driven by turbines. They all in all record for 30+ Tons of fresh water every day separated from the day by day necessities of 10+ ton for crew consumption as drinking, cooking, washing,Tank cleaning and different utilities. Adequate consumable water might be taken up against the cargo load capacity in the port for satisfying crew and machinery necessity yet isn't prescribed to utilize shore water for boilers because of their low quality, so Fresh water generator is unavoidable on board ship.

But why do we need the FWG on board in first place?

In the middle of good old days people used to bring across lots of water in their ship. It was good however it expands the load on the ship and furthermore water lack issues were always there. Be that as it may, the nature of shore water will be extremely (too much) bad to be used in water tube boiler and filling (expansion) tanks. The storage space that could have been used for fresh water can as a result be used for fuel or added/more space for payload and products (that are bought and sold) when fresh water generator is installed on a ship. As you may know the first (or most important) concern for running a ship or any transportation business is to make money. Further more Boiler needs demineralized water to reduce overall scale development and corrosion issues. It is also normally used to build the general efficiency of the running machinery, mostly it uses the engine warmth/heat by Cooling The Hot Jacket Cooling Water At Around 85 Deg Celsius To 65 Deg Celsius.

Working Principal Of FWG?


Extremely important rule of all low weight freshwater generator is that, boiling point of water can be decreased by lessening the pressure of the air surrounding it. By keeping up a low pressure, water can be bubbled at low temperatures say 55 degree Celsius. The source of warmth for the fresh water generator could be waste heat rejected by generators and main engine jacket cooling water. This decrease In Saturation Temp lead to early vaporisation of water due to vacuum created within the chamber. It Is Created By The Help Of An Air Ejector, Which Extracts The Air From That compartment/chamber. An Air Ejector Works On Bernoulli's Rule and being used side by side with a brine ejector used to suck salt water from the chamber. The vacuum help disappear the water leaving behind the salt or salt water to be sucked by salt water ejector. It is then passed through the dimmister (A sort of punctured plate with very minute gaps) which traps any water or salt particle traveling through it. The evaporated water is then condensed together with the help of ocean water and after that tested for sality with the help of salino-meter.


Regulations Regarding Production of sea water on board ship:


  1. Ship must be 12 nautical miles away from the nearest coastline to start the FWG.
  2. Engine must be running at full ahead sea speed during start of FWG.
  3. Ensure main engine parameters are normal.
  4. Ship is not in congested water.
  5. Ship is not maneuvering.
  6. There is no oil/chemical spill reported in the visinity of the ship.

Safety Equipments on A Typical FWG:

1. Vacuum Breaker For Releasing Vacuum when we shut down the FWG.

2. Relief Valve For Releasing The Excess Pressure.

3. High Salinity Alarm: It Is Fitted To The Salinometer As It Measures Higher Salt Content In The Water Produced.

4. Temperature Gauge.

Starting Procedures for Fresh water generator:


  • First we need to ensure that suction, discharge and overboard valves for ejector pumps are under open condition. Now once been checked, start the ejector pump.
  • Close the vacuum breaker valve.
  • Make Sure the S.W pressure at ejector (air) is not less than 3 bar. Now wait for 10-15 minutes to build vacuum in the generation chamber of fresh water generator. Wait until it shows more than 90% vacuum.
  • Now open the sea water feed to the evaporator. Check for the sea water level in the shell through the sight glass and ensure it is at optimum level controlling feed through feed valve. Once the heating coils are fully submerged by the sea water open the J.C.W valves to the evaporator slowly.
  • Purge out any air in the system by opening air vent at the top of the evaporator.
  • Check for evaporation from the sight glass and then start the salinometer.
  • Divert the outlet back to the feed water until the salinity is under the limit.
  • When the salinity level is as per the desired or set value, open the discharge valve of distillate pump which sends the water to the fresh water holding tank through flow meter.
  • Increase the evaporation rate and start the discharge pump. Check for the sytem to be stable.



Author Amit                                                          Article requested by: NIÑO GONZALES


What is marine boiler and Boiler system on oil tankers.

What is marine boiler and how it works on oil tankers.

A boiler is a closed pressure vessel, in which water vapor is produced from distilled water / feed water. All boilers have a furnace or a combustion chamber in which fuel is combusted to release energy. Air is provided in the boiler furnace for assisting the combustion of the fuel. A large clearance between the combustion chamber and the water allows the transfer of combustion energy to the water, as heat. The boilers are equipped with a steam drum and a water drum, which ensure steam and water respectively, can be separated. It should also provide a variety of accessories and to ensure that the fuel, the supply of air and water is to meet the steam requirements.

VARIOUS USES OF STEAM ON SHIPS

For main engine propulsion/turbines (in case of steam ships)
For power generation (to run steam turbo generators)
For running auxiliaries (in case of steam ships)
For soot blowing and for the steam atomized burners.
For fresh water generation (Evaporators)
For fire major fighting (steam drenching)
For heating duties (ME fuel oil heater, Galley supply, Purifier, Calorifier, Galley, Accommodation heating, Sea chests tracer lines for pipeline heating)
For cargo heating
For fuel tank heating
For deck machineries
For running Cargo pump turbines
For operating bilge, stripping and other steam driven pumps.
For tank washing in tanker ships and general cleaning.
For using as a steam ejector media for ejector pumps and vacuum devices
For Driving steam driven deck machineries like winches etc.

Pressures used:
The working pressure used in marine boilers will vary from boiler to boiler as required.For Tanker Vessels Medium pressure 17-30 bar(normally 16bar).

Boiler system in oil tankers:

Boiler system in oil tankers

Due to the high demand in the oil-Tankers, high capacity composite boilers or Dual pressure boilers are used. The main reason for the introduction of double pressure boiler is the use of modern boiler water pipes of high yield, without fear of load damage or contamination of Fuel oils. The basic construction is made of a D-Type boiler design upon which is mounted a Steam/Steam generator drum. Steam heating by the main boiler warms the water in the steam generator which full fill all the requirements for a propulsion pump, the heating load and fuel tanks and all other tasks of turbines.

The drum is initially filled with the primary quality of feed water and is well balanced. Make-up is limited to small amounts due to leaks and the fuel pump can be simple. An example of this could be an alternative pump driven by steam or air. The chemical treatment/dozing is simple and requires only minimal for the addition or rinsing. The above design shows super heater in the system but this is usually installed where the generated steam is required for the turbine alternators.
Secondary drum.

The U-shaped heating elements welded through the door of the shaft and at the end covered with the drum head. The tubes are well supported. In the lower part of the housing a manhole can be installed to allow access to the heating elements. The secondary drum also acts as a receiver for the exhaust gases of the steam boiler. Typical pressures above 63 bar (278degC) for the primary and 23.5deg (219degC) for the secondary. Primary pressure of 35bar (242degC) and closer to 15bar high pressure (198degC) proved to be sufficient to drive turbines for cargo oil pumps on tankers.

Composite boilers

On another hand Composite boilers are a combination of oil boilers and exhaust gas economiser. When the diesel engine is at full load, the fuel burner starts only when the steam demand is higher than the production of steam from the exhaust gas of diesel engines. Composite boilers are so arranged that these can generate steam on Main engine exhaust gases or by burning oil in the furnace. In most cases the gas flows are kept separate each having its own uptake this permits the oil firing to be used in conjunction with the engine exhaust gases. By this means the output of steam can be maintained independent of the engine power.

Most of the tank type auxiliary boilers can be modified for composite firing, the modification consists of an additional tube nest added to basic oil fired design, the engine exhaust gases are circulated thru this tube nest so providing heat for generation of steam. In port stays boiler pressure is controlled by start/stop of burner at required pressure, and during sailing the pressure control is by excess steam dump valve.

But on which principle D-type water tube boiler work?

D-type water tube boiler

This boiler has 2 drums, an integral furnace with wall mounted burners and is often referred to as ‘D’ type boiler because of its shape. The furnace is at the side of the 2 drums and is surrounded on all sides by water tube walls. These water wall tubes are connected either to upper and lower headers or a lower header and the steam drum. The larger steam drum is placed above a smaller water drum , The two drums are connected to a large number of pipes of small diameter, which carry feed water. These small diameter pipes are known as the generating tubes that provide the main heat transfer surfaces for the generation of steam. The water circulates between the two drums with the aid of large diameter downcomers. The superheater is located through several rows of screen tubes covered between the drums. The fireproof material is used in the manufacture of the furnace, the burner wall and behind the water walls. The fire-resistant material acts as an insulator, which prevents heat loss. The boiler is also provided with a jacket for the combustion air, around the air control registers, which are surrounded by the burner.

# Various books, study material and other online sources has been refereed prior to writing this article but no part is copied or produced  from any of the source but explained same thing in better detailed way.

Author Arpit Singh                                                                             Article requested by: bilal ahmad